Secondary Ion Mass Spectrometry |
|
|
|
Business,Business News,Business Opportunities
|
|
History In 1910 British physicist J. J. Thomson observed a release of positive ions and neutral atoms from a solid surface induced by ion bombardment. Improved vacuum pump technology in the 1940s enabled the first prototype experiments on SIMS by Herzog and Viehbck in 1949, at the University of Vienna, Austria. Then in the early 1960s two SIMS instruments were developed independently. One was an American project, led by Liebel and Herzog, which was sponsored by NASA at GCA Corp, Massachusetts, for analyzing moon rocks, the other at the University of Paris-Sud in Orsay by R. Castaing for the PhD thesis of G. Slodzian. These first instruments were based on a magnetic double focusing sector field mass spectrometer and used argon for the primary beam ions. In the 1970s, K. Wittmack and C. Magee developed SIMS instruments equipped with quadrupole mass analyzers. Around the same time, A. Benninghoven introduced the method of static SIMS, where the primary ion current density is so small that only a negligible fraction (typically 1%) of the first surface layer is necessary for surface analysis. Instruments of this type use pulsed primary ion sources and time-of-flight mass spectrometers and were developed by Benninghoven, Niehus and Steffens at the University of Mnster, Germany and also by Charles Evans & Associates. Recent developments are focusing on novel primary ion species like C60 or ionized clusters of gold and bismuth. Instrumentation Typical schematic of a dynamical SIMS instrument. High energy ions are supplied by an ion gun (1 or 2) and focused on to the target sample (3), which ionizes and sputters some atoms off the surface. These secondary ions are then collected by ion lenses (5) and filtered according to atomic mass (6), then projected onto an electron multiplier (7, top), Faraday cup (7, bottom), or CCD screen (8). Typically, a secondary ion mass spectrometer consists of: primary ion gun generating the primary ion beam primary ion column, accelerating and focusing the beam onto the sample (and in some devices an opportunity to separate the primary ion species by Wien filter or to pulse the beam) high vacuum sample chamber holding the sample and the secondary ion extraction lens mass analyser separating the ions according to their mass to charge ratio ion detection unit. Vacuum SIMS requires a high vacuum with pressures below 104 pascal (roughly 106 mbar or torr). This is needed to ensure that secondary ions do not collide with background gases on their way to the detector (i.e. the mean free path of gas molecules within the detector must be large compared to the size of the instrument), and it also prevents surface contamination by adsorption of background gas particles during measurement. Primary ion sources There are three basic types of ion guns. In one, ions of gaseous elements are usually generated with Duoplasmatrons or by electron ionization, for instance noble gases (Ar+, Xe+), oxygen (O-, O2+), or even ionized molecules such as SF5+ (generated from SF6) or C60+. This type of ion gun is easy to operate and generates roughly focused but high current ion beams. A second source type, the surface ionization source, generates Cs+ primary ions. Caesium atoms vaporize through a porous tungsten plug and are ionized during evaporation. Depending on the gun design, fine focus or high current can be obtained. A third source type, the liquid metal ion source (LMIG), operates with metals or metallic alloys, which are liquid at room temperature or slightly above. The liquid metal covers a tungsten tip and emits ions under influence of an intense electric field. While a gallium source is able to operate with elemental gallium, recently developed sources for gold, indium and bismuth use alloys which lower their melting points. The LMIG provides a tightly focused ion beam (<50 nm) with moderate intensity and is additionally able to generate short pulsed ion beams. It is therefore commonly used in static SIMS devices. The choice of the ion species and ion gun respectively depends on the required current (pulsed or continuous), the required beam dimensions of the primary ion beam and on the sample which is to be analyzed. Oxygen primary ions are often used to investigate electropositive elements due to an increase of the generation probability of positive secondary ions, while caesium primary ions often are used when electronegative elements are being investigated. For short pulsed ion beams in static SIMS, only LMIGs are deployable, but they are often combined with either an oxygen gun or a caesium gun for sample depletion. Mass analyzers Dependent on the SIMS type, there are three basic analyzers available: sector, quadrupole, and time-of-flight. A sector field mass spectrometer uses a combination of an electrostatic analyzer and a magnetic analyzer to separate the secondary ions by their mass to charge ratio. A quadrupole mass analyzer separates the masses by resonant electric fields, which allow only the selected masses to pass through. The time of flight mass analyzer separates the ions in a field-free drift path according to their kinetic energy. It requires pulsed secondary ion generation using either a pulsed primary ion gun or a pulsed secondary ion extraction. It is the only analyzer type able to detect all generated secondary ions simultaneously, and is the standard analyzer for static SIMS instruments. Detectors A Faraday cup measures the ion current hitting a metal cup, and is sometimes used for high current secondary ion signals. With an electron multiplier an impact of a single ion starts off an electron cascade, resulting in a pulse of 108 electrons which is recorded directly. A microchannel plate detector is similar to an electron multiplier, with lower amplification factor but with the advantage of laterally-resolved detection. Usually it is combined with a fluorescent screen, and signals are recorded either with a CCD-camera or with a fluorescence detector. Detection limits and sample degradation Detection limits for most trace elements are between 1012 and 1016 atoms per cubic centimeter, depending on the type of instrumentation used, the primary ion beam used and the analytical area, and other factors. Samples as small as individual pollen grains and microfossils can yield results by this technique. The amount of surface cratering created by the process depends on the current (pulsed or continuous) and dimensions of the primary ion beam. While only charged secondary ions emitted from the material surface through the sputtering process are used to analyze the chemical composition of the material, these represent a small fraction of the particles emitted from the sample. Static and dynamic modes In the field of surface analysis, it is usual to distinguish static SIMS and dynamic SIMS. Static SIMS is the process involved in surface atomic monolayer analysis, usually with a pulsed ion beam and a time of flight mass spectrometer, while dynamic SIMS is the process involved in bulk analysis, closely related to the sputtering process, using a DC primary ion beam and a magnetic sector or quadrupole mass spectrometer. Applications The COSIMA instrument onboard Rosetta will be the first instrument to determine the composition of cometary dust with secondary ion mass spectrometry in 2014. See also SHRIMP References ^ Thomson, J. J (1910). "Rays of positive electricity". Phil. Mag. 20: 752767. ^ Herzog, R. F. K., Viehboeck, F (1949). "Ion source for mass spectrography". Phys. Rev. 76: 855856. doi:10.1103/PhysRev.76.855. ^ Liebl, H. J (1967). "Ion microprobe mass analyzer". J. Appl. Phys. 38: 52775280. doi:10.1063/1.1709314. ^ Castaing, R. & Slodzian, G. J (1962). "Optique corpusculaireremiers essais de microanalyse par emission ionique secondaire". Microscopie 1: 395399. ^ Wittmaack, K. (1975). "Pre-equilibrium variation of secondary ion yield". Int. J. Mass Spectrom. Ion Phys. 17: 3950. ^ Magee, C. W. et al. (1978). "Secondary ion quadrupole mass spectrometer for depth profiling design and performance evaluation". Rev. Scient. Instrum. 49: 477485. PMID 18699129. ^ Benninghoven, A (1969). "Analysis of sub-monolayers on silver by secondary ion emission". Physica Status Solidi 34: K169171. doi:10.1002/pssb.19690340267. ^ S.Hofmann (2004). "Sputter-depth profiling for thin-film analysis". Phil. Trans. R. Soc. Lond. A 362: 5575. doi:10.1098/rsta.2003.1304. ^ "SIMS Detection Limits of Selected Elements in Si and SiO2 Under Normal Depth Profiling Conditions". Evans Analytical Group. May 4, 2007. http://www.eaglabs.com/files/appnotes/AN339.pdf. Retrieved 2007-11-22. ^ Kaufman, A.J.; Xiao, S. (2003). "High CO2 levels in the Proterozoic atmosphere estimated from analyses of individual microfossils". Nature 425: 279282. doi:10.1038/nature01902. ^ C. Engrand, J. Kissel, F. R. Krueger, P. Martin, J. Siln, L. Thirkell, R. Thomas, K. Varmuza (2006). "Chemometric evaluation of time-of-flight secondary ion mass spectrometry data of minerals in the frame of future in situ analyses of cometary material by COSIMA onboard ROSETTA". Rapid Communications in Mass Spectrometry 20: 13611368. doi:10.1002/rcm.2448. Bibliography Benninghoven, A., F. G. Rdenauer, and H. W. Werner, "Secondary Ion Mass Spectrometry: Basic Concepts, Instrumental Aspects, Applications, and Trends", Wiley, New York, 1987 (1227 pages) ISBN 0471519456 Bubert, H., Jenett, H., "Surface and Thin Film Analysis; A compenium of Principles, Instrumentation, and Applications", p. 86-121, Wiley-VCH, Weinheim, Germany 2002 ISBN 3-527-30458-4 External links Annual SIMS workshop - site includes a literature database. Tutorial pages for SIMS theory and instrumentation Time-of-Flight SIMS - tutorial slide presentation. Presentation by Dr. Charles Magee A Historical Perspective of SIMS. Categories: Mass spectrometry Semiconductor analysis I am China Manufacturers writer, reports some information about shoe storage rack , wooden drawers.
Related Articles -
shoe storage rack, wooden drawers,
|
Rate This Article |
|
|
|
Do you Agree or Disagree? Have a Comment? POST IT!
Reader Opinions |
|
|
|
|
|
|
|
|
Author Login |
|
|
Advertiser Login
ADVERTISE HERE NOW!
Limited Time $60 Offer!
90 Days-1.5 Million Views
|
|
PAUL PHILIPS
For more articles, blog messages & videos and a free e-book download go to www.NewParadigm.ws your p...more
|
|
|
|
|
TIM FAY
After 60-plus years of living, I am just trying to pass down some of the information that I have lea...more
|
|
|
|
|
LAURA JEEVES
At LeadGenerators, we specialise in content-led Online Marketing Strategies for our clients in the t...more
|
|
|
|
|
ADRIAN JOELE
I have been involved in nutrition and weight management for over 12 years and I like to share my kn...more
|
|
|
|
|
GENE MYERS
Author of four books and two screenplays; frequent magazine contributor. I have four other books "in...more
|
|
|
|
|
DONNIE LEWIS
I'm an avid consumer of a smoothie a day living, herbs, vitamins and daily dose of exercise. I'm 60...more
|
|
|
|
|
ALEX BELSEY
I am the editor of QUAY Magazine, a B2B publication based in the South West of the UK. I am also the...more
|
|
|
|
|
SUSAN FRIESEN
Located in the lower mainland of B.C., Susan Friesen is a visionary brand strategist, entrepreneur, ...more
|
|
|
|
|
STEPHEN BYE
Steve Bye is currently a fiction writer, who published his first novel, ‘Looking Forward Through the...more
|
|
|
|